8 Channel Temperature Data Logger

8 Channel Multi-Sensor Temperature Data Logger with onboard memory card writes temperature data to removable CompactFlash® card

8 Channel Multi-Sensor Temperature Data Logger with removable CompactFlash card.The USB-5203 is a temperature logger that provides 8 temperature inputs and supports all of the common sensor types — thermocouples, RTDs, thermistors and semiconductor temperature sensors. Temperature measurements can be stored onto a 64MB Compact Flash card. The data can then be read and downloaded either by removing the CF card and inserting it into a CF reader, or by connecting the device up to a PC via the USB port.

The USB-5203 logger can be configured via the USB port using the included InstaCal software. The data can be analyzed and charted using our powerful TracerDAQ software, available in a full range of options--from no programming to graphical programming to custom programming.

8 Channel Multi Sensor Data Logger includes:
>> USB Power Adapter and US Plug
>> 64 MB CompactFlash® Card
>> USB Cable
>> Universal Library
>> Universal Library for LabView
>> InstaCal and TracerDAQ 2.0 Software

NOTE: Large Quantity Discounts Are Available!

Note: Any order for Measurement Computing Products to be Shipped Outside the US will require an "End User Export Agreement" form to be Completed and Returned Prior to Products being Shipped.

Features   Applications   Specifications   Documentation

Description Part Number Qty 1-9 Qty 10+  
MCC 8-Channel Temperature Data Logger USB-5203
$729.00 call
Optional Thermocouples
6ft.Beaded Type J Thermocouple w/ connector TC6-J
$19.00 $18.00
6ft. Beaded Type K Thermocouple w/ connector TC6-K
$19.00 $18.00
6ft. Beaded Type T Thermocouple w/ connector TC6-T
$19.00 $18.00
12" Probe Type K Thermocouple w/connector - 6 ft. cable TCP6-K12
$39.00 $37.00
Subminiature Connector for Type J Wire SMC-J
$9.00 call
Subminiature Connector for Type K Wire SMC-K
$9.00 call
Subminiature Connector for Type T Wire SMC-T
$9.00 call
Patch Style Thermocouple Type J PST-J
$25.00 $20.00
Patch Style Thermocouple Type K PST-K
$25.00 $20.00
Patch Style Thermocouple Type T PST-T
$25.00 $20.00
Type K 24 Gauge 3 ft Long Thermocouple Probe (Limited Quantity - 1 Available) 08515-01
$21.00 call
Type T 24 Gauge 3 ft Cable Length Thermocouple Probe (Limited Quantity - 11 Available) 08515-02--U--
$21.00
$17.00
call
Type K 24 Gauge 10ft Cable Length Thermocouple Probe 08516-82
$29.00 $24.00
Optional Logger Accessories
2.5 Watt USB Power Adapter with US Plug USB_Power_Adapter
$29.00 call
CompactFlash® Card Reader CF_Card_Reader
$29.00 call
US Plug US_Plug
$9.00 call
UK Plug UK_Plug
$9.00 call
European Plug Europe_Plug
$9.00 call
Australian Plug Australian_Plug
$9.00 call
128 MB CF Card 128MB_CF_CARD
$29.00 call
256 MB CF Card 256MB_CF_CARD
$49.00 call
512 MB CF Card 512MB_CF_CARD
$69.00 call
1 GB CF Card 1GB_CF_CARD
$119.00 call
2 GB CF Card 2GB_CF_Card
$239.00 call
Keyspan USB Server for connecting USB-based Devices ( Data Logger ) over a LAN US-4A
$129.00 call
Type K Pipe Clamp Temperature Probe TP200
$39.00 call
Optional Software
Das-Wizard Software for USB DAQ Devices Das-Wizard
$149.00 call
DASYLab Lite DAQ Software DASYLab_Lite
$499.00 call
DASYLab Basic DAQ Software DASYLab_Basic
$1,299.00 call
DASYLab Full DAQ Software DASYLab_Full
$1,799.00 call
DASYLab Pro DAQ Software DASYLab_Pro
$2,499.00 call
Additional DASYLab Runtime License DASYLab_Runtime
$449.00 call

Temperature Data Logger Features

  • 8 multi-sensor input channels
  • Portable without a need for a dedicated PC or laptop
  • Supports thermocouples, RTDs,Thermistors and Semiconductor Temperature Sensors
  • Superior performance - accuracy exceeds sensor output
  • Includes 64-MB CompactFlash® card & USB power Adapter and software
  • 8 Digital I/O Channels for configuring High/Low Alarms
  • Independent temperature inputs
  • Built-in ambient temperature sensor
  • User configurable in internal memory for alarming
  • Keyspan USB Server is Required for Ethernet Connectivity

Temperature Logger Applications

  • Warehouses and Vehicle Cargo Spaces
  • HVAC and Refrigeration
  • Mold Control
  • Greenhouses and Nurseries
  • Wine Cellars
  • Documentation Storage

Temperature Logger Specifications

Maximum Logging Rate/Channel 2 Samples per second to PC
1 Sample per second to CF card
A/D Converters Four (4) Dual 24-bit Sigma-Delta type
Number of Channels 8 Differential Channels
Input Isolation 500 VDC minimum between field wiring and USB interface
Channel configuration Software programmable to match sensor type
Differential Input Voltage Range Thermocouple ±0.080 Volts
RTD 0 to 0.5 Volts
Thermistor 0 to 2 Volts
Semiconductor Sensor 0 to 2.5 Volts
Absolute Maximum Input Voltage ±25 Volt power on
±40 Volt power off
Input Impedance 5 Gigohm Minimum
Input Leakage Current Disabled Open Thermocouple Detect 30 nA Maximum
Enabled Closed Thermocouple Detect 105 nA Maximum
Normal Mode Rejection Ratio 90 dB Minimum
Common Mode Rejection Ration 100 dB Minimum
Resolution 24 Bits
Input Coupling DC
Warm-up Time 30 Minutes Minimum
Open Thermocouple Detect Automatically enabled when the channel pair is configured for thermocouple sensors. The maximum open detection time is 3 seconds.
CJC Sensor Accuracy 15 °C to 35 °C ±0.25 °C Typical
±0.5 °C Maximum
0 °C to 70 °C -1.0 to +0.5 °C Maximum
Digital Input/Output Type CMOS
Number of Digital I/O 8 (DIO0 to DIO7)
Digital I/O Configuration Independently configured for input or output.
Power on reset is input mode unless bit is configured for alarm.
Digital Pull up/Pull down Configuration All pins pulled up to +5 V via 47 K resistors (default). Pull down to ground (GND) also available.
Digital I/O Transfer Rate
(software paced)
Digital Input - 50 port reads or single bit reads per second typical.
Digital Output - 100 port writes or single bit writes per second typical.
Digital Input High Voltage High Voltage: 2.0 V Minimum; 5.5 V absolute Maximum
Low Voltage: 0.8 V Maximum; -0.5 V absolute Minimum
Digital Output Low Voltage (IOL = 2.5 mA): 0.7 V Maximum
High Voltage (IOH = -2.5mA): 3.8 V Minimum
Alarm Input Modes 1. Alarm when input temperature > T1
2. Alarm when input temperature > T1, reset alarm when input temperature goes below T2
3. Alarm when input temperature < T1
4. Alarm when input temperature < T1, resetalarm when input temperature goes above T2
5. Alarm when input temperature is < T1 or > T2
NOTE: T1 and T2 may be independently set for each alarm.
Alarm Output Modes Disabled: Digital I/O line may be used for normal operation.
Enabled: Active High Output (Digital I/O line goes high when a alarm conditions met)
Enabled: Active Low Output (Digital I/O line goes low when alarm conditions met)
Alarm Update Rate 1 Second
Standalone Power Supply USB Power Adapter
2.5 Watt USB Adapter with Interchangeable Plugs
(Includes Plug for USA)
Memory Card Type CompactFlash®
Storage Capacity 2GB Maximum
File System Format DOS FAT-16; the memory card must be formatted by the device prior to use for logging. The device only creates 8.3 file names and a flat directory structure ( no subdirectories). The memory card is readable by Windows operating systems after device format/use.
Logging Rate Minimum 1 second between entries, Maximum 232 seconds, 1 second granularity
Data Items Logged Timestamp,temperature or raw reading from selected channels, state of DIO lines, CJC Sensor Readings
Logging Start Methods Configurable:
1. Start Logging on Power Up - Logging begins 5 seconds after power on to allow hardware to settle.
2. Start Loggin on Button - Device is idle on power on. Press and hold button until LED comes on to begin logging. The first sample will be taken 1 second after LED comes on unless less than 5 seconds have elapsed since power on.
3. Start Logging at Specified Time - Device is idle until the real tme clock indicates the time is equal to or greater than the specified time, at which time the LED with come on. The first sample will be taken 1 second after LED comes on unless less than 5 seconds have elapsed since power on.

NOTE: Data Logging is not allowed when the device is attached to an active USB bus due to processing limitations. The device must be connected to the standalone pwer supply to perform data logging.
Logging Stop Methods Stop on button Press - To stop logging, press and hold button until LED turns off.

NOTE: The device caches log data in volatile memory prior to writing to memory card. When logging, always use the button to stop logging and ensure data is written to memory card prior to removing power.
Logging Status Indication The LED operations when connected to the AC Adapter power supply are different than when connected to USB:

Logging modes:
1. Logging Off mode: the LED is off (disabled).
2. Start Logging on Power Up mode: the LED is on, with a momentary off flash every time data is captured.
3. Start Logging on Button mode: the LED is initially off. When the button is pressed and held for approxiamately 1 second the LED will turn on and act the same as Start Logging on Power Up mode.
4. Start Logging at Specified Time mode: the LED is off, with a momentary on flash every second until the specified date/time is reached. At that time, the LED will turn on and act the same as Start Logging on Power Up mode.

Other indication:
To Stop logging and store the remaining data to memorycard, press and hold the button until the LED turns off. It is then safe to remove the memory card.
If the memory card becomes full the LED will blink rapidly (250 ms period).
If the memory card is removed while logging is in progress the LED will blink rapidly (250 ms period). Inserting a memory card will stop the blinking.
Operating Temperature Range 0 to 70°C
Storage Temperature Range -40 to 85°C
Humidity 0 to 90% non-condensing
Dimensions 127mm (L) x 88.9mm (W) x 35.56mm (H)

Download and view the detailed specifications
Quick Start Guide
USB-5203 User Manual

Optional Thermocouples available
1. Beaded Thermocouple Probes
2. High Temperature Stainless Steel Probes
3. Subminiature Thermocouple Connectors
4. Patch Style Thermocouples
5. PVC Insulated Thermocouples
6. Teflon FEP Insulated Probes
Details on these thermocouples are available here.

Optional RTDs available
1. 100 ohm PT (DIN 43760: 0.00385 ohms/ohm/°C)
2. 100 ohm PT (SAMA: 0.003911 ohms/ohm/°C)
3. 100 ohm PT (ITS-90/IEC751:0.0038505 ohms/ohm/°C)

Optional Thermistors available
1. Standard 2,252 ohm through 30,000 ohm thermistor sensors

Optional Semiconductor Temperature Devices available
1. TMP36 or equivalent Sensors

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax