Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

GL200A Midi Data Logger

GL200A Midi Data Logger

The GL200A midi data logger accepts voltage, temperature, humidity, pulse and logic signals. The sensors are connected via rear mounted screw terminals. With its channel-to-channel isolation, wiring errors or overloaded channels will not affect neighbouring channels. Its built-in 3.5MB non-volatile memory retains data even if the power supply is interrupted. The included software provides real-time waveform monitoring, data upload and data export to spreadsheets.

Included With Each Midi Logger
>> OPS022 Software
>> 100 to 240 Volt (50/60 Hz) AC Adapter

Optional Accessories Available
>> Humidity Sensor (#B-530)
>> 6 Hour Battery Pack (#B-517)
>> DC Power Cable (#B-514)
>> USB 1.1 Memory Stick for additional 1GB of data storage

Features   Specifications  Documentation

NOTE: Large Quantity Discounts available!

Description Part Number Qty 1-9 Qty 10+  
GL200A Midi Logger GL200A
$995.00 call
Optional Accessories
Graphtec Battery Pack B-517
$120.00 call
Cable: 4x logic inputs, 4x alarm outputs, 2 meters B-513
$80.00 call
DC Power cable, 2 meters, bare ends, for direct connection to DC power source B-514
$50.00 call
Graphtec Humidity Sensor B-530
$400.00 call
Yellow Xtreme Protective Case (11.93" x 9.02" x 4.02") T6000.2
$63.00 call
Black Xtreme Protective Case (11.93" x 9.02" x 4.02") T6000.3
$63.00 call
Cole Parmer 12" Length Cable Adapter, Type K 93786-02
$15.00 call

Midi Logger Features

  • Accepts Voltage, Temperature, Humidity, Pulse and Logic Inputs
  • Sampling Rate up to 10ms when 1 Channel is Used
  • 16-bit ADC Resolution
  • 3.5" Color LCD Display (320 x 240 pixels)
  • Waveform and text display modes
  • Easy-to-use keypad menu system
  • Single open-collector alarm output
  • Range of trigger functions
  • Real-time Statistical Calculation
  • Built-in 3.5M Memory
  • 2 x USB 2.0 interfaces - one for USB Memory stick and one for PC connection
  • Optional battery (#B517) for 6 hour operation
  • Maximum Sampling Rate of 0.1s/sec for each Channel
  • 1 Pulse, 1 Logic and 1 Trigger Input Available
  • Small Size: 194mm x 122mm x 41mm
  • Supplied with mains PSU (AC Adapter)
  • Includes Windows software for setup, control, data transfer, data conversion to ASCII and Excel formats, and on-screen data review with cursors

GL200A Logger Specifications

Number of Input Channels Analog: 10 Channels
Pulse: 1 Channel*
Logic: 1 Channel*
*Maximum Input Voltage: +24V
*Input Threshold Voltage: Approximately +2.5 Volts
*Hystersis: Approximately 0.5 Volts (+2.5V to 3.0V)
Sampling Interval 10ms to 1 hr (10ms to 50ms are for voltage measurement only, with limit to number of channels)
Input Method Photo MOS Relay Scanning System; All Channels Common Ground (Channel to Channel Isolation: Wiring Errors or Overloaded Channels have no affect on Neighboring Channels)
Measurement Ranges Voltage: 20, 50, 100, 500mV; 1,2,5,10,20,50V; 1 to 5 v FS
Temperature: Thermocouples Type K,J,T,R,S,B,N,W
Humidity: 0-100% (Voltage 0V to 1V Scaling Conversion)
Scan Speed 0.1 Seconds/10 Channel Maximum
Trigger Functions Trigger Types: Start/Stop: Data Capture Starts/Stops When a trigger is generated
Trigger Conditions: Off, Level, External, Date/Time, Specified Period of Time (Stop Only)
Alarm Functions Type: Analog, Logic or Pulse; OR Logic
Conditions:
Rising, Falling, Window In, Window Out (Analog, Pulse)
Rising, Falling (Logic)
Alarm Output Number of Channels: 1 Channel
Output Format: Open Collector Output (100kΩ pull-up resistance)
Output Conditions: Level, Window, Logic Pattern and Pulse Judgement
Pulse Input Mode RPM Mode: Counts the number of pulses per second; enables them to be converted to rpms.
Count Mode: Displays a count of the number of pulses fro each sampling interval from the start of measurement
Inst. Mode: Counts the number of pulses for each sampling interval. Resets the count value after each sampling interval.
Pulse Input Range RPM Mode: 50 rpm, 500 rpm, 5000 rpm , 50 krpm, 500 krpm, 5 Mrpm, 50 Mrpm, 500 Mrpm
Count Mode: 50 c, 500 c, 5000 c, 50 kc, 500 kc, 5 Mc, 50 Mc and 500 Mc
Inst. Mode: 50 c, 500 c, 5000 c, 50 kc, 500 kc, 5 Mc, 50 Mc and 500 Mc
Internal Memory Capacity 3.5 MB
External Memory Device USB Memory Stick
PC Interface USB 2.0
Display Size: 3.5" TFT Color LCD (320 x 240 pixels)
Displayed Items: Waveforms + Digital Values, Waveforms Only, Digital Values Only, Digital Values + Calculated Values
Functions: Waveform Expansion/Compression, Scaling, Calculatons, Search
A/D Converter 16-bit (14 are internally acknowledged)
Input Impedance 1M Ohms ±5%
Withstand Voltage Between Input Terminals and Chassis 1 Minute at 350V p-p
Maximum Input Voltage Between ± Terminals: 60V p-p
Between Input Terminals and Casing: 60V p-p
Operating Environment Temperature: 0 to 40°C
Humidity: 30 to 80% RH (Non-condensing)
Power Supply AC Adapter: 100 to 240 VAC, 50/60 Hz (Included)
DC Input: (8.5 to 24VDC)
Battery Pack: (Optional)
Dimensions 194mm x 122mm x 41mm
Weight 480g (Excludes AC Adapter and Battery)

Humidity Sensor Specifications (#B-530)

Measurement Range Temperature: -25 to 80C
Humidity: 0-100% RH
RH Accuracy 3%RH (5 to 98%RH at 25C)
Response Time 15 seconds (90% Rtesponse When Membrane Filter Installed)
Output 0 to 1 Volt DC
Power Source 5 to 16 Volts DC
Power Consumption Approx. 4 mA
Dimensions 14mm x 80mm
Cable Length 3 Meters

Battery Pack Specifications (#B-517)

Capacity 7.2 Volts/2200 mAh
Battery Type Lithium Scondary Battery
Running Time Up to 2 Packs can be Mounted
When LCD is On:
Battery Pack x 1 (Brightness MAX): Approx. 2.5 Hours
Battery Pack x 1 (Brightness MIN): Approx. 3.0 Hours
Battery Pack x 2 (Brightness MAX): Approx. 5.0 Hours
Battery Pack x 2 (Brightness MIN): Approx. 6.0 Hours
When LCD is Off:
Battery Pack x 1: Approx. 4.5 Hours
Battery Pack x 2: Approx. 9.0 Hours
Note: When Capturing to Internal Memory at 1 s, sampling, 20 channel terminals, using new battery packs at 25C Environment.
Note: The Running Time Depends on the Operating Environment.
Charging Method Mount in the Main Unit
Time Required for Charging Battery Pack x 1: Approx. 4.0 Hours
Battery Pack x 2: Approx. 8.0 Hours
Switchover in the Case of a Power Failure Because the Battery is Used Together with the AC Adapter, the Power Supply will be Switched Automatically to the Battery in the Event of a Power Failure.
Note: The AC Adapter is the Primary Power Source.
Operating Environment 15°C to 40°C
Other Functions >> When Battery is Running Low, File is Closed Automatically
(When Captured to Internal Memory or USB Memory)
>> Remaining Amount Indicator

GL200A User Manual

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax