Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

SmartReader Plus 4 Differential Logger

ACR 2 Channel Data Logger: Low Pressure Differential and Temperature

SmartReader Plus 4 - Low Pressure Differential Data Logger: 2 Channels - Low Pressure Differential and TemperatureThe ACR Low Pressure Differential SmartReader Plus 4 data logger is designed to be used in applications where precise and very low differential pressure measurements are required.

Required with Temperature Data Logger
>> TrendReader 2 software

Required for Ethernet Connectivity
>> TrendReader 2 Software with USB Cable Kit (#TR2-USB)
>> Keyspan USB Server
>> Read the Networking and Remote Communications Guide

NOTE: NIST Calibration is available.
Large Quantity Discounts Are Available!

Features   Specifications   Application Notes   Fast Sample Rates

Description Part Number Qty 1-9 Qty 10+  
SmartReader Plus 4 32KB, 2-channels: one differential pressure 0.5" WC, one temp SRP-004-LPD-0-5
$950.00 call
SmartReader Plus 4 32KB, 2-channels: one differential pressure 1" WC, one temp SRP-004-LPD-1
$950.00 call
SmartReader Plus 4 32KB, 2-channels: one differential pressure 2" WC, one temp SRP-004-LPD-2
$950.00 call
SmartReader Plus 4 32KB, 2-channels: one differential pressure 5" WC, one temp SRP-004-LPD-5
$950.00 call
SmartReader Plus 4 32KB, 2-channels: one differential pressure 10" WC, one temp SRP-004-LPD-10
$950.00 call
Software Kit - 1 Required
TrendReader 2 Software with RS-232 Cable (IC-101) and Manual for Smart Reader series TR2-RS232
$230.00 call
TrendReader 2 Software with USB Interface Cable (IC-102) and Manual for Smart Reader series TR2-USB
$240.00 call
TrendReader 2 Software CD Only (interface cable and manual not included), for SmartReader Plus, Smart Reader, IAQ and OWL Loggers TR2-Standard
$130.00 call
Standard NIST Calibration Service
Standard NIST Temperature Calibration (1 Point) CAL-NIST-TEMP $40.00Temp:
Optional Accessories
Fast Sampling Battery Pack BP-101
$54.00 call
Network/Fast Sampling Power Supply - 120V - North American Version PS-201-NA
$66.00 $53.00
Network/Fast Sampling Power Supply - 220V - European Version PS-201-EU
$76.00 $60.00
Extra RS-232 Interface Cable for SmartReader, SmartReader Plus and Nautilus loggers IC-101
$119.00 call
Keyspan USB Server for connecting USB-based Devices ( Data Logger ) over a LAN US-4A
$129.00 call
USB Serial Adapter Cable-USB232
$39.00 $35.00
Keyspan USB 4-Port Serial Adapter USA-49WG
$149.00 call

SmartReader Plus 4 Logger Features

  • Extremely Accurate
  • 10 Year Battery Life
  • Data Storage Capacity of 21,500 Readings
  • 2 Channels

SmartReader Plus 4 Logger Specifications

General Specifications
Channels Two (one for the internal temperature sensor and one for the internal pressure sensor)
Memory Size 32 KB (21,500 readings)
Size 107 x 74 x 22 mm. (4.2” x 2.9” x 0.9”)
Weight 110 grams (3.75 ounces)
Case Material Noryl Plastic
External Connector Removable screw-type terminal strip with Common (-) connection
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy ±2 seconds per day
Battery 3.6 volt Lithium, 1 Amp-Hour
Battery Life 10 year warranty (under normal use), factory replaceable
Power Consumption 5 to 10 microamps (continuous)
Sampling Methods 1. Continuous (First-in, First-out – not available with sample rates faster than 8 seconds)
2. Stop when full (Fill-then-stop)
Sampling Rates User selectable rates from 25 per second to 1 reading every 8 hrs. (BP-101 Battery Pack or PS-201 Power Supply required for sample rates faster than 8 seconds)
Resolution 12 bit (1 part in 4,096)
Mounting Magnetic backing or locking eyelet
PC Requirements IBM PC or 100% compatible running MS Windows 3.1, ’95, ’98, 2000, Me, NT, XP or Vista 32-bit with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port.
Software Requirements TrendReader Software and Interface Kit
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets radiated and conducted emission require ments for the Interference Causing Equipment Standard for Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE).
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5”.

Pressure Sensor
Type Silicon piezoresistive strain gauge
Media Non-corrosive gases and dry air
Maximum Pressure Four times full scale

Pressure Sensor Ranges Available
Range Accuracy Resolution
± 0.5" WC (± 120 Pa) ± 0.05" WC (± 2.5 Pa) < 0.001" WC (0.25 Pa)
± 1" of WC (± 250 Pa) ± 0.05" WC (± 2.5 Pa) < 0.001" WC (0.25 Pa)
± 2" of WC (± 500 Pa) ± 0.05" WC (± 2.5 Pa) < 0.001" WC (0.25 Pa)
± 5" of WC (± 1.2 kPa) ± 0.1" WC (± 12.5 Pa) < 0.01" WC (2.5 Pa)
± 10" of WC (± 2.5 kPa) ± 0.1" WC (± 12.5 Pa) < 0.01" WC (2.5 Pa)

Internal Temperature Sensor
Type Negative Temperature Coefficient Thermistor.
10,000 ohms @ 25°C (77°F)
Accuracy ± 0.2°C, over the range of 0 to 70°C (±0.3°F over the range of 32 to 158°F)
Range -40 to 70°C (-40 to 158°F)
Resolution 0.03°C (0.05°F) at 25°C (77°F). Better than 0.07°C
(0.12°F) between -25°C (-13°F) and 70°C (158°F).
Better than 0.13°C (0.23°F) between -40°C (-40°F)
and -25°C (-13°F)

SmartReader Plus 4 Logger Application Notes

Fast Sampling with Battery Pack or External 120 Volt Power Supply
For sampling rates faster than once every 8 seconds, the Smart Reader Plus data loggers require the use of an external 120 volt power supply (#PS-201) or fast sampling battery pack (#BP-101).

The fast sampling battery pack has replaceable "AAA" batteries and 8" (20cm) cable attached, with a male stereo jack on the end. The stereo jack is plugged into the communication port on the Smart Reader Plus data logger.

The 120 Volt Power Supply is required when network length is greater than 50' , more than 3 loggers are on the network, or for sampling rates greater than 8 seconds on the SmartReader Plus Loggers.

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax