SmartReader 6 Data Logger
ACR Seven Channel Data Logger: One Ambient Temperature and 6 Thermocouple Channels
The SmartReader 6 data logger is ideal for those applications that require
multi-site temperature monitoring of extremely high temperatures or wide
temperature ranges. This datalogger has one internal channel for measuring ambient
temperature and six external channels for use with ACR thermocouple wire or any J,
K, S or T type thermocouple wire.
Required with SmartReader 6 Data Logger
>> TrendReader 2 Software
Required for Ethernet Connectivity
>> TrendReader 2 Software with USB Cable Kit (#TR2-USB)
>> Keyspan USB Server
NOTE: NIST Calibration is available. Large Quantity Discounts Are Available!
Features Specifications
| Description |
Part Number |
Qty 1-9 |
Qty 10+ |
|
| SmartReader 6W seven channel temperature (thermocouple) logger, wide range |
SR-006W
|
$899.00 |
call |
 |
| Software Kit - 1 Required |
| TrendReader 2 Software with RS-232 Cable (IC-101) and Manual for Smart Reader series |
TR2-RS232
|
$230.00 |
call |
 |
| TrendReader 2 Software with USB Interface Cable (IC-102) and Manual for Smart Reader series |
TR2-USB
|
$240.00 |
call |
 |
| TrendReader 2 Software with LIC-101, Manual and Serial Interface Cable for OWL Series |
TR2-LIC
|
$230.00 |
call |
 |
| TrendReader 2 Software CD Only (interface cable and manual not included), for SmartReader Plus, Smart Reader, IAQ and OWL Loggers |
TR2-Standard
|
$130.00 |
call |
 |
| Standard NIST Calibration Service |
| Optional Accessories |
| Keyspan USB Server for connecting USB-based Devices ( Data Logger ) over a LAN |
US-4A
|
$129.00 |
call |
 |
| USB Serial Adapter |
Cable-USB232
|
$39.00 |
$35.00 |
 |
| Keyspan USB 4-Port Serial Adapter |
USA-49WG
|
$149.00 |
call |
 |
SmartReader 6 Logger Features
- Data Storage Capacity of 32,000 Readings
- 7 Seperate Channels
- 10 year battery life
SmartReader 6 Logger Specifications
| General Specifications |
| Channels |
Seven (one internal thermistor for cold-junction compensation and six
external channels for thermocouple inputs) |
| Memory |
32 KB (32,767 readings) |
| Size |
107 x 74 x 22 mm. (4.2" x 2.9" x
0.9") |
| Weight |
110 grams (3.75 ounces) |
| Case Material |
Noryl Plastic |
| External Connector |
Removable screw-type terminal strip with Common (-) connection |
| Mounting |
Magnetic backing or locking eyelet |
| Operating Limits |
-40°C to 70°C (-40°F to 158°F)
and 0 to 95%
Relative Humidity (non-condensing) |
| Clock Accuracy |
±2 seconds per day |
| Battery |
3.6 volt Lithium, 1 Amp-Hour |
| Battery Life |
10 year warranty (under normal use), factory
replaceable |
| Power Consumption |
5 to 10 microamps (continuous) |
| Sampling Methods |
1. Continuous (First-in, First-out)
2. Stop when full (Fill-then-stop) |
| Sampling Rates |
User selectable rates from 8 seconds to
once every 5 days |
| Resolution |
8 bit (1 part in 256) |
| PC Requirements |
IBM PC or 100% compatible running Windows
3.1,
’95, ’98, 2000, Me, NT or XP with at least
2 MB RAM,
2 MB of hard drive disk space and one free serial port |
| Software Requirements |
TrendReader
2 Software and Interface Cable |
| Certifications and Standards |
- Certified to CE standard EN50082-1: 1992 (European
Generic Immunity) covering ESD, RFI and EFT/B
-Meets CE standards EN55011 Class B: 1991 (European Radiated
Emissions) and CISPR Class B: 1991(International Radiated
Emissions)
|
| Resistance to X-Rays |
- Tested for protection against a 160kV dose
@ 5mA for 30
seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times
that of an airport x-ray machine)
- Tested for protection
against Gamma Ray (equivalent to 0.137-1.38 mega volts)
IR 192 - 28 curies @ 30 second exposure source to object
distance 5” |
| Internal Temperature Sensor |
| Type |
Negative Temperature Coefficient Thermistor.
10,000 ohms @ 25°C (77°F) |
| Accuracy |
± 0.2°C, over the range of 0 to
70°C
(±0.3°F over the
range of 32 to 158°F) |
| Range |
-40 to 70°C (-40 to 158°F) |
| Resolution |
0.4°C (0.7°F) at 25°C (77°F); better than
1 °C
(1.8°F) between -25°C and 70°C
(-13°F and 158°F);
better than 2.0°C (3.6°F) between -40°C
and -25°C (-40°F and -13°F) |
| Thermocouples Accepted |
| Type |
Channel |
Range |
Resolution |
| J |
Channel #2 (Wide) |
-50 to 600°C (-55 to 1100°F) |
5°C (9°F) |
| K |
Channel #2 (Wide) |
-100 to 900°C (-145 to 1650°F) |
6.7°C (12°F) |
| S |
Channel #2 (Wide) |
0 to 1760°C (32 to 3200°F) |
23°C (41.5°F) |
| T |
Channel #2 (Wide) |
-200 to 400°C (-325 to 750°F) |
6.7°C (12°F) |
| Accuracy ± 1% of Range + Resolution |
MicroDAQ.com accepts Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax
|