SmartReader 5 Data Logger
ACR Three Channel Data Logger: One Ambient Temperature and 2 Thermocouple Channels
The SmartReader 5 data logger is ideal for those applications that require
monitoring extremely high temperatures or monitoring temperature
over a wide range. The logger has one internal channel for
measuring ambient temperature and two external channels for
use with ACR thermocouple wire or any J, K, S or T type thermocouple
wire.
Required with Smart Reader 5 Data Logger
>> TrendReader 2 Software
Required for Ethernet Connectivity
>> TrendReader 2 Software with USB Cable Kit (#TR2-USB)
>> Keyspan USB Server
NOTE: NIST Calibration is available. Large Quantity Discounts Are Available!
Features Specifications
| Description |
Part Number |
Qty 1-9 |
Qty 10+ |
|
| SmartReader 5 Three Channel Temperature (thermocouple) logger |
SR-005
|
$479.00 |
call |
 |
| Software Kit - 1 Required |
| TrendReader 2 Software with RS-232 Cable (IC-101) and Manual for Smart Reader series |
TR2-RS232
|
$230.00 |
call |
 |
| TrendReader 2 Software with USB Interface Cable (IC-102) and Manual for Smart Reader series |
TR2-USB
|
$240.00 |
call |
 |
| TrendReader 2 Software with LIC-101, Manual and Serial Interface Cable for OWL Series |
TR2-LIC
|
$230.00 |
call |
 |
| TrendReader 2 Software CD Only (interface cable and manual not included), for SmartReader Plus, Smart Reader, IAQ and OWL Loggers |
TR2-Standard
|
$130.00 |
call |
 |
| Standard NIST Calibration Service |
| Optional Accessories |
| Keyspan USB Server for connecting USB-based Devices ( Data Logger ) over a LAN |
US-4A
|
$129.00 |
call |
 |
| USB Serial Adapter |
Cable-USB232
|
$39.00 |
$35.00 |
 |
| Keyspan USB 4-Port Serial Adapter |
USA-49WG
|
$149.00 |
call |
 |
SmartReader 5 Logger Features
- Monitoring performance of gas fired heating equipment
- Verifying concrete curing temperatures
- Process verification
Other Thermocouple Data Loggers from ACR
SmartReader 5 Logger Specifications
| General Specifications |
| Channels |
Three (one internal thermistor for cold-junction compensation
and two external channels for narrow range and wide range thermocouples) |
| Memory |
32 KB (32,767 readings) |
| Size |
107 x 74 x 22 mm. (4.2” x 2.9” x
0.9”) |
| Weight |
110 grams (3.75 ounces) |
| Case Material |
Noryl Plastic |
| External Connector |
Removable screw-type terminal strip with Common (-) connection |
| Mounting |
Magnetic backing or locking eyelet |
| Operating Limits |
-40°C to 70°C (-40°F to 158°F)
and 0 to 95%
Relative Humidity (non-condensing) |
| Clock Accuracy |
±2 seconds per day |
| Battery |
3.6 volt Lithium, 1 Amp-Hour |
| Battery Life |
10 year warranty (under normal use), factory replaceable |
| Power Consumption |
5 to 10 microamps (continuous) |
| Sampling Methods |
1. Continuous (First-in, First-out)
2. Stop when full (Fill-then-stop) |
| Sampling Rates |
User selectable rates from 8 seconds to
once
every 5 days |
| Resolution |
8 bit (1 part in 256) |
| PC Requirements |
IBM PC or 100% compatible running Windows
3.1,
’95, ’98, 2000, Me, NT or XP with at least
2 MB RAM,
2 MB of hard drive disk space and one free serial port |
| Software Requirements |
TrendReader
2 Software and Interface Cable |
| Certifications and Standards |
- Certified to CE standard EN50082-1: 1992 (European
Generic Immunity) covering ESD, RFI and EFT/B
-Meets CE standards EN55011 Class B: 1991 (European Radiated
Emissions) and CISPR Class B: 1991(International Radiated
Emissions)
|
| Resistance to X-Rays |
- Tested for protection against a 160kV dose
@ 5mA for 30
seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times
that of an airport x-ray machine)
- Tested for protection
against Gamma Ray (equivalent to 0.137-1.38 mega volts)
IR 192 - 28 curies @ 30 second exposure source to object
distance 5” |
| Internal Temperature Sensor |
| Type |
Negative Temperature Coefficient Thermistor.
10,000 ohms @ 25°C (77°F) |
| Accuracy |
± 0.2°C, over the range of 0 to
70°C (±0.3°F over the range of 32 to 158°F) |
| Range |
-40 to 70°C (-40 to 158°F) |
| Resolution |
0.4°C (0.7°F) at 25°C (77°F); better than
1 °C
(1.8°F) between -25°C and 70°C
(-13°F and 158°F);
better than 2.0°C (3.6°F) between -40°C
and -25°C (-40°F and -13°F) |
| Thermocouples Accepted |
| Type |
Wide/Narrow |
Range |
Resolution |
| J |
Channel #2 (Wide) |
-50 to 600°C (-55 to 1100°F) |
5°C (9°F) |
| Channel #1 (Narrow) |
-20 to 190°C (0 to 370°F) |
1.4°C (2.5°F) |
| K |
Channel #2 (Wide) |
-100 to 900°C (-145 to 1650°F) |
6.7°C (12°F) |
| Channel #1 (Narrow) |
-25 to 230°C (-10 to 440°F) |
1.7°C (3°F) |
| S |
Channel #2 (Wide) |
0 to 1760°C (32 to 3200°F) |
23°C (41.5°F) |
| Channel #1 (Narrow) |
0 to 960°C (32 to 1750°F) |
7°C (12.6°F) |
| T |
Channel #2 (Wide) |
-200 to 400°C (-325 to 750°F) |
6.7°C (12°F) |
| Channel #1 (Narrow) |
-35 to 200°C (-30 to 390°F) |
1.7°C (3°F) |
| Accuracy: ± 1% of
range + resolution |
MicroDAQ.com accepts Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax
|